Ariston double-circuit gas boiler - features and advantages. Instructions for gas wall-mounted boilers Ariston Ariston boiler description

When conducting overhaul installation may be required new system heating. Today we offer a huge range of heating boilers, the differences between which lie in the fuel used, the manufacturer’s power, etc. Note that the greatest demand is for the Ariston double-circuit gas boiler, which has excellent technical characteristics and accessibility.

Gas equipment manufactured by Ariston

Gas equipment produced by Ariston, depending on the model in question, is designed for installation in autonomous heating systems with an area of ​​up to 500 m2. Note that these models are capable of not only heating the coolant, but also capable of providing the user with hot water supply.

The Ariston double-circuit wall-mounted gas boiler is distinguished by its compact external dimensions, as well as simplicity and ease of operation and maintenance. To install the equipment, you do not need to allocate a separate room, as, for example, for liquid and solid fuel heating devices.

Thanks to the wide power range, Ariston equipment can be easily selected for installation in specific system, based on the characteristics of the room that will be heated.

List of required functions in heating equipment

  1. The language menu on absolutely all models offers Russian.
  2. The AUTO function is installed, which allows you to automatically adjust the power based on the internal and external air temperatures.
  3. Absolutely all Ariston units have heat and sound insulation.
  4. The manufacturer provides a two-year warranty on all its traditional-type products, and a three-year warranty on condensation products.

Equipment safety is ensured by the following built-in functions:

  • semi-automatic refill;
  • pumping air out of the system;
  • blocking the operation of the circulation pump;
  • protection against freezing and scale formation.

Ariston double-circuit turbocharged gas heating boilers are characterized by simplicity and ease of operation and maintenance.

The main advantages of Ariston equipment

Ariston equipment is offered in two versions: wall-mounted and floor-mounted. The former are used for installation in heating systems of private houses, in which, in addition to heating, it is important to obtain hot water. Depending on the model, the equipment may be:

  • with an open combustion chamber (combustion products are removed naturally);
  • With closed camera combustion (removal is carried out by forced means).

Equipment with a closed chamber is connected to a coaxial chimney. The difference is that these models have a built-in fan, thanks to which combustion products are removed in a timely manner.

The main advantage of devices of the second type is high safety, and also in the fact that air is taken from outside the room, while devices of the first type take the oxygen necessary for normal gas combustion from the room.

It is important to note that Ariston double-circuit wall-mounted gas boilers stop working to heat the coolant immediately after the fence is turned on hot water. This point is important to consider when choosing and purchasing a device.

Floor-standing appliances have a large power range. This equipment is ideal for use in systems autonomous heating residential premises of any size. As a rule, floor-standing units are not designed to heat water, so if this issue is relevant to you, you will have to buy a separate boiler.

Design features and equipment design

All proposed gas boiler options differ in the type of combustion chamber: closed or open. If the device is equipped with an open chamber, then it will need to be connected to the chimney, while air is taken from the room in which the unit is installed.

If the Ariston wall-mounted double-circuit gas heating boiler is equipped with a closed chamber, then the combustion products are removed forcibly using a built-in fan. Such equipment is connected to a coaxial chimney. Air is taken from outside the room, which is a big advantage, since the oxygen in the room is not burned during operation of the device.

Gas wall mounted double-circuit boilers Ariston heating systems have two heat exchangers in their design. One is intended for heating process water, the second for heating the coolant. Their production can be carried out in several versions: bithermic, separate and with a built-in boiler.

Main characteristics of Ariston gas boilers

  • the device menu is displayed in Russian; if necessary, you can easily set the required temperature for heating the coolant and hot water;
  • high resistance to sudden changes in voltage in the network;
  • the equipment will continue to operate stably even with reduced water and gas pressure in the relevant systems;
  • ease and convenience in installation, maintenance and operation;
  • high efficiency in operation.

As for the shortcomings of the equipment, it is important to note the inability to simultaneously work on heating the coolant and sanitary water, but this problem, if desired, can be easily solved by installing a boiler.

The Ariston double-circuit wall-mounted gas boiler can have in its design special sensors for determining internal and external air temperatures. All operating parameters are displayed on the built-in display, which makes it easy to monitor work processes and, if necessary, make the required adjustments to them.

Causes of malfunctions of gas-type boilers

Even if the operating instructions for the Ariston gas boiler are thoroughly studied, it is impossible to insure against the fact that the device breaks down. There are many reasons why equipment can fail, for example:

  • maintenance the instrument was not completed in a timely manner or with violations;
  • insufficient air supply to the combustion chamber;
  • unprofessional repairs or maintenance of control units or burner regulation;
  • low-quality spare parts were used during maintenance;
  • Incorrectly set temperature.

There are other more complex breakdowns of gas heating boilers that should only be repaired by an employee service department. Therefore, regardless of the complexity and cause of the malfunction, the Ariston double-circuit gas boiler must be repaired and serviced by a technician who has not only special tools and experience, but also special permission to carry out repairs and maintenance of gas heating boilers.

Do not save on the purchase, installation and connection of gas equipment; trust all work processes only to professionals.

Gas boiler Ariston Genus EV - video

The most popular models of Ariston gas boilers

Genus Premium 35 NG is a condensing type device that is easy to program various modes work. The advantage of the equipment is high efficiency. Ariston double-circuit gas boilers, equipped with a closed combustion chamber, ensure high safety and operational reliability of the equipment.

Exhaust gases are discharged through a coaxial chimney forcibly. It is important to note that the equipment is capable of self-diagnosis, which allows you to quickly identify a malfunction and take measures to eliminate it.

The Egis 24 CF NG (EAA1) equipment is equipped with an open combustion chamber. The unit is connected to a chimney, the diameter of which must be greater than 12.5 cm. The design of the device contains two heat exchangers. Installation type: wall mounted.

Ariston Clas is highly economical in operation. Today, options are offered whose power can range from 24 to 28 kW.

The combustion chamber in Ariston Clas can be closed or open. The design of the device includes two heat exchangers. The main advantage is the ability to continue to work stably even with a sharp drop in pressure in the gas main or water supply system.

If you decide to buy an Ariston wall-mounted double-circuit gas boiler of any other series, you can be sure that the equipment you purchase will also be distinguished by its quality, reliability and efficiency in operation.

Features of choosing heating equipment

When choosing heating boilers, it is important to take into account the height of the ceilings, the area of ​​​​the premises, the material from which the structure is built and interfloor ceilings, quality of window blocks. Many useful information You can find out if you carefully study the operating instructions for the Ariston gas boiler. By correctly determining all the above mentioned parameters, you can find out what power the device will be most profitable to purchase.

Calculations should be performed according to the following scheme. If, for example, a house has an area of ​​150 m2 with a ceiling height of 2.7 - 3 meters, the windows, ceilings and walls are well insulated, then at the rate of 1 kW per 10 m2, we get 15 kW of device power, to which it is recommended to add 10 %. As a result, we will obtain the maximum required power of the heating equipment. If, in addition to heating, there is a need for hot water supply, then 4 kW of power should be added to the result obtained.

In addition to the considered parameter, there are others, which in no case should be forgotten when choosing. Therefore, if you doubt that you can correctly cope with the choice of a gas boiler, then contact a specialist who, taking into account all the requirements and features of the house in which the device will be installed, will select it according to all the necessary parameters.

On this page you can find and download instructions for Ariston gas wall-mounted boilers in pdf format.

      Gas wall-mounted boilers Ariston series GENUS 24 FF, GENUS 28 FF, GENUS 36 FF, GENUS 24 CF, GENUS 28 CF. Operating instructions. Language: RU, RO | pdf 786.93 Kb

      Ariston gas wall-mounted boilers of the GENUS 24 CF, GENUS 28 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.09 Mb

      Ariston gas wall-mounted boilers of the GENUS 24 FF, GENUS 28 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.07 Mb

      Gas wall-mounted boilers Ariston series GENUS 24 FF, GENUS 28 FF. Installation and maintenance instructions. Language: RU, RO | pdf 5.05 Mb

      Gas wall-mounted boilers Ariston series GENUS 24 CF, GENUS 28 CF. Installation and maintenance instructions. Language: RU, RO | pdf 3.14 Mb

      Gas wall-mounted boilers Ariston GENUS 36 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 893.17 Kb

      Gas wall-mounted boilers Ariston GENUS 36 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.00 Mb

      Gas wall-mounted boilers Ariston series GENUS 24 CF, GENUS 28 CF, GENUS 24 FF, GENUS 28 FF, GENUS 35 FF. Operating instructions. Language: RU, RO | pdf 7.32 Mb

      Wall-mounted single-circuit boilers CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF. Installation and maintenance instructions. 2008 | pdf 4.71 Mb

      Gas wall-mounted single-circuit boilers CLAS System 15 FF, CLAS System 24 FF, CLAS System 28 FF, CLAS System 32 FF, CLAS System 15 CF, CLAS System 24 CF, CLAS System 28 CF. Operating instructions. 2008 | pdf 1.24 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 CF. Installation and maintenance instructions. 2008 | pdf 1.01 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF. Installation and maintenance instructions. 2008 | pdf 1.24 Mb

      Gas wall-mounted double-circuit boilers EGIS 24 FF, EGIS 24 CF. Operating instructions. 2008 | pdf 497.92 Kb

      Gas wall-mounted boilers Ariston series BS 24 FF, BS 24 CF. Operating instructions. Language: RU, PL | pdf 439.96 Kb

      Gas wall-mounted boilers Ariston BS 24 CF series. Installation and maintenance instructions. Language: RU, PL | pdf 1.86 Mb

      Gas wall-mounted boilers Ariston BS 24 CF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.05 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series for heating and hot water supply. Passport. Language: RU, PL | pdf 1.08 Mb

      Gas wall-mounted boilers Ariston BS 24 FF series. Installation and maintenance instructions. Language: RU, PL | pdf 2.33 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series. Operating instructions. Language: RU, UA, RO | pdf 228.38 Kb

      Gas wall-mounted boilers Ariston BS II 15 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.71 Mb

      Gas wall-mounted boilers Ariston BS II 15 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1012.93 Kb

      Gas wall-mounted boilers Ariston BS II 24 FF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.88 Mb

      Gas wall-mounted boilers Ariston BS II 24 FF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1018.39 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series for heating and hot water supply. Passport. Language: RU, UA, RO | pdf 1005.51 Kb

      Gas wall-mounted boilers Ariston BS II 24 CF series. Installation and maintenance instructions. Language: RU, UA, RO | pdf 1.38 Mb

      Gas wall-mounted boilers Ariston series BS II 24 FF, BS II 24 CF. Operating instructions. Language: RU, UA, RO | pdf 246.76 Kb

      Gas wall-mounted boilers Ariston series CLAS 24 FF, CLAS 28 FF, CLAS 24 CF. Operating instructions. Language: RU, RO | pdf 661.98 Kb

      Gas wall-mounted boilers Ariston CLAS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.28 Mb

      Gas wall-mounted boilers Ariston CLAS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1005.77 Kb

      Ariston gas wall-mounted boilers of the CLAS 24 FF, CLAS 28 FF series for heating and hot water supply. Installation and maintenance instructions. Language: RU, RO | pdf 2.78 Mb

      Ariston gas wall-mounted boilers of the CLAS 24 FF, CLAS 28 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1.13 Mb

      Gas wall-mounted boilers Ariston series CLAS B, CLAS B Premium: CLAS B 24 CF, CLAS B 24 FF, CLAS B 30 FF, CLAS B Premium 24, CLAS B Premium 35. Operating instructions. Language: RU, PL, CZ, RO, HU | pdf 2.52 Mb

      Gas wall-mounted boilers Ariston CLAS B 24 CF series. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 7.20 Mb

      Gas wall-mounted boilers Ariston CLAS B 24 CF series for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.09 Mb

      Ariston gas wall-mounted boilers of the CLAS B 24 FF, CLAS B 30 FF series for heating and hot water supply. Installation and maintenance instructions. Language: RU, PL, CZ, RO, HU | pdf 8.84 Mb

      Ariston gas wall-mounted boilers of the CLAS B 24 FF, CLAS B 30 FF series for heating and hot water supply. Passport. Language: RU, PL, CZ, RO, HU | pdf 1.15 Mb

      Ariston gas wall boilers of the CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF series. Operating instructions. Language: RU, RO | pdf 373.49 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF. Installation and maintenance instructions. Language: RU, RO | pdf 1.87 Mb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 CF, CLAS EVO SYSTEM 24 CF, CLAS EVO SYSTEM 28 CF for heating and hot water supply. Passport. Language: RU, RO | pdf 987.40 Kb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF. Installation and maintenance instructions. Language: RU, RO | pdf 2.60 Mb

      Gas wall-mounted boilers Ariston series CLAS EVO 24 FF, CLAS EVO 28 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 28 FF, CLAS EVO SYSTEM 32 FF for heating and hot water supply. Passport. Language: RU, RO | pdf 990.97 Kb

      Ariston gas wall boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF, CLAS EVO SYSTEM 15 CF, CLAS EVO SYSTEM 24 CF series. Operating instructions. Language: RU | pdf 306.18 Kb

      Ariston gas wall boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF series. Installation and maintenance instructions. Language: RU | pdf 2.33 Mb

      Ariston gas wall boilers of the CLAS EVO SYSTEM 15 FF, CLAS EVO SYSTEM 24 FF, CLAS EVO SYSTEM 32 FF series for heating and hot water supply. Passport. Language: RU | pdf 946.87 Kb

      Gas wall-mounted boilers Ariston series EGIS PLUS 24 FF, EGIS PLUS 24 CF. Operating instructions. Language: RU, RO | pdf 204.57 Kb

      Gas wall-mounted boilers Ariston EGIS PLUS 24 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.29 Mb

      Gas wall-mounted boilers Ariston EGIS PLUS 24 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 973.91 Kb

      Gas wall-mounted boilers Ariston EGIS PLUS 24 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 934.35 Kb

      Gas wall-mounted boilers Ariston EGIS PLUS 24 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 1.69 Mb

      Ariston gas wall boilers of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF, GENUS EVO 24 CF, GENUS EVO 30 CF series. Operating instructions. Language: RU, RO | pdf 446.18 Kb

      Ariston gas wall boilers of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF series for heating and hot water supply. Passport. Language: RU, RO | pdf 991.20 Kb

      Ariston gas wall-mounted boilers of the GENUS EVO 24 CF, GENUS EVO 30 CF series for heating and hot water supply. Passport. Language: RU, RO | pdf 1019.57 Kb

      Ariston gas wall boilers of the GENUS EVO 24 FF, GENUS EVO 30 FF, GENUS EVO 32 FF, GENUS EVO 35 FF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.72 Mb

      Ariston gas wall boilers of the GENUS EVO 24 CF, GENUS EVO 30 CF series. Installation and maintenance instructions. Language: RU, RO | pdf 2.19 Mb

Nowadays, everyone is trying to make their life more comfortable. And the first thing you need to start with is installing a double-circuit gas wall-mounted boiler Ariston. This is very practical equipment, since it can be used to heat your own private house, or an apartment, or huge premises with an area of ​​up to 500 m².

These boilers can not only heat the room in the cold season, but also heat water for household use. This is very convenient, since you don’t have to additionally connect the boiler, for which you need to choose a separate place. Ariston wall-mounted boilers are extremely easy to use and easy to install. Therefore, both a professional and a beginner in this matter can cope with such work - you just need to first read the instructions for the Ariston boiler.

Rice. 1

It is also very good that Ariston manufactures gas boilers for almost any operating conditions. After all, in our country, natural gas pressure drops are not news, but rather a common thing. There may also be sudden changes in temperature - and all this is a wall-mounted boiler for heating Ariston withstands.

Features of Ariston gas boilers

Which one is the most main part in a double-circuit gas boiler? Yes, this is his burner, which burns fuel (in our case gas) and also releases it into the system thermal energy, which heats the room.

The burner is:

  • Regular.
  • Modulation.

The second option is more common and convenient, since thanks to it, the system of the Ariston gas wall-mounted boiler is automatically regulated. That is, the power of heating equipment depends on its temperature. There is also this one mandatory system, as a removal of combustion products.

Therefore, the boiler burner is:

  • Closed.
  • Open.

Ariston gas boilers with a closed burner are safer heating equipment, since combustion products will never enter the room. They also do not require a chimney. All you need to do is connect it to the boiler coaxial pipe, which can easily be taken outside. Ariston double-circuit gas boilers with an open burner require a chimney, since combustion products must be removed. And for this you need natural traction. Air will also be taken from the room, so it must be constantly ventilated.

The good thing about a coaxial pipe (for a closed combustion chamber) is that it is made of so-called two layers. This design coaxial chimney good because combustion products escape through the pipe, but at the same time fresh air enters the burner of the Ariston boiler. This means that oxygen will not be taken from the room.


Rice. 2

What else are good about Ariston double-circuit boilers? And the fact that they are not one heat exchanger, as in single-circuit ones, but two. One is intended for heating the room, and the other is for heating water. Ariston company produces various options boilers They can contain separate heat exchangers, duothermal, and also have a built-in water heater tank.

What other features are there in Ariston gas boilers:

  • They have a water pump to circulate water through the pipes. Availability expansion tank also available in many models. Thanks to it, the pressure in the heating system is normalized without outside help.
  • This heating equipment may have various types ignition Ignition can be either fully automatic, which makes working with the boiler much easier, or piezo-ignition. In the second option, to operate the heating system, you need to press a button to start the unit.
  • Any model Ariston automation and protection systems.

Advantages of Ariston boilers

There is a wide variety of different heating units on the market for this equipment. Therefore, each person will be able to choose a model that suits their wallet. But why Ariston? But because people, when they come home, want to be alone with themselves and enjoy the silence. And gas units from this company are able to satisfy this desire.

Compatriots began to trust these products more and more. And for good reason. After all, the Ariston double-circuit gas unit operates almost silently. Thanks to him, bills for public utilities will be minimal, since this boiler is a fairly economical unit. Fuel is used in minimal quantities.

You will receive a system that supplies you hot water around the clock, and also heats your apartment or house for a minimal fee. Also, the units of the Italian brand last longer than what is written on the warranty. By purchasing such a device, you will forget about exchanging the boiler for many decades. It is also very good that Ariston units are compact in size, so there is a place for it in absolutely any size apartment or private house.

How to choose gas heating equipment

The Ariston product catalog contains many models, which, if you look at them, it’s hard to make right choice. Many people, when they come to a store for this equipment, make mistakes, since they do not have all the necessary information before purchasing a wall-mounted unit. Therefore, recommendations on choosing a boiler from this company will be written below.

Rice. 3

Each model has many technical features, and, of course, because of this, choosing the right heating device becomes increasingly difficult. At first glance, it may seem that gas units are similar to each other, but only a professional can understand the intricacies. So you can contact a specialist by choosing an Ariston boiler, or you can read the information and try to make the right choice yourself.

So, what you need to consider before choosing quality equipment:

  • Of course, everyone knows the size of their kitchen, or the place where the heating unit will be installed. Therefore, the first thing to do is to consider what sizes of boilers are available, select the most optimal ones, and only then move on to the technical features.
  • Next, you need to take into account what kind of water heater is in the gas appliance, because most models with a low price have instantaneous water heater. This means that if you have a large family, then such a double-circuit boiler is not suitable for home use.
  • It’s better to choose a hot water storage tank – how many liters it will hold is up to you to decide. The storage tank heats a large volume of water, which is then used for quite a long time.
  • There are two types of combustion chambers in Ariston gas units. These are a closed combustion chamber and an open combustion chamber. Of course, it is better to choose a boiler with a closed combustion chamber. This heating unit does not use room oxygen, so it is safer for health. Plus, you still don’t have to install a chimney. It is enough to purchase a coaxial pipe and lead it through the wall. But since such a boiler is more expensive, not everyone can afford to buy it. Although if you think about your health, it’s better to save up cash and buy a really high-quality product.

In just a few decades, Ariston has leapt ahead thanks to high quality of its products. You can constantly look at new models and be amazed at how quickly technology develops. Choosing a boiler is really difficult, but the right information will help you with this.

Types of heating boilers Ariston

All heating units from this company have three series. They differ from each other in some technical features.

So what are the series? famous brand:

  • Genus- These are the most developed models. They have more features than models in other series. The Genus device kit includes: primary and secondary heat exchangers, as well as a fan that smoothly regulates the speed. All Genus wall-mounted boilers have an LCD screen sufficiently large sizes. On it you can see all the data on which the gas unit operates.
  • Clas– powerful and large (volume) heating units. They have a built-in regulator that supplies gas. Thanks to it, you can regulate gas flow. This is very convenient especially for those who are often away from home.
  • Egis. All heating models from this series are small (compact) in size and very attractive in appearance. Their design will decorate any interior. They also have high level Efficiency, which allows you to reduce utility costs. Intelligent system controls also have gas apparatus Ariston Egis series.

Rice. 4

Technical characteristics of Ariston gas boilers

All boilers of this brand have a power of 15 to 30 kW. You can choose exactly the power that is suitable for the size of your house or apartment.

So, technical features wall-mounted heating units:

  • the very good thing is that the menu of wall-mounted boilers for Russian citizens also available in Russian. Therefore, you can easily set the temperature that should be;
  • in places where power surges often occur, these Ariston heating devices are best suited. They can withstand them without problems;
  • Gas units also cope well with reduced gas and water in systems.
  • gas double-circuit units are easy to operate. They are also easy to install, so even a beginner can handle it.
  • they have a high level of efficiency and are quite economical.

Of course, there is the possibility that the boiler will not be able to heat at the same time heating system and water, but this is not big problem. Since, if necessary, you can install a boiler in parallel to heat water.

Rice. 5

Some gas models wall equipment may even have sensors that detect indoor and outdoor air temperatures, so they work even more efficiently. The built-in display will show all the parameters by which the unit operates, so you can correct everything in time.

For what reasons does an Ariston gas boiler fail?

There are options when all connection and operation parameters have been met, but the heating boiler is still faulty? Like all equipment, gas units can also fail.

There are reasons for this:

  • a malfunction may occur due to the fact that some maintenance rules were violated, or the installation was unsuccessful;
  • Malfunctions of the Ariston gas double-circuit boiler also occur when there is insufficient air supply. The combustion chamber must constantly receive air in order for it to operate at full capacity. If there is not enough of it, then, accordingly, various problems with the operation of the boiler will appear;
  • Malfunctions may also appear due to incorrect work carried out by specialists when servicing the control units or adjusting the burner;
  • The market is full of low-quality products, so spare parts are also often found to be of low quality. Even if the installation or replacement of something went well, a malfunction can still appear precisely because of imperfect spare parts.

This is not the entire list of breakdowns that can occur with a gas unit. But one condition for repairing all models of Ariston boilers must be fulfilled - calling a specialist who understands such issues to your home. Working with gas equipment is far from a safe task, which is why it must be carried out by experienced employees who have permits for repairs and all the necessary spare parts.

Instructions for using Ariston gas boilers

If you are not a professional in the field of installing gas heating units and do not understand anything about their installation, then you should definitely contact experienced specialists who will help you solve these problems. Firstly, they have all the necessary permits, and secondly, they will give you instructions, thanks to which you will “find a common language” with heating boilers.

Children or those who have not been instructed in the use of the units should not be allowed to access gas equipment. Because this is fraught with various consequences. If you are going to go somewhere for for a long time, then after turning off the boiler, it is necessary to close all the valves on the pipes (gas shut-off valve and water supply shut-off valve). Then you need to turn it off gas equipment for heating from the network.

During operation of wall-mounted units, it is necessary to monitor all readings that are displayed on the display. The display of wall-mounted heating devices shows all the problems and errors that occurred during the operation of the boiler. The safety precautions that are written in the instructions must be observed not only with a double-circuit gas boiler, but also with other gas equipment.

Advantages and disadvantages of Ariston gas boilers

Wall-mounted heating units, like any other equipment, have their pros and cons. But, of course, there are more advantages. And if you also follow all the operating rules, then there will be much fewer disadvantages. The models of this company are both wall-mounted and floor-mounted. Wall-mounted boilers are more popular equipment, since they are intended mainly for heating private houses, apartments, cottages, etc.

Wall-mounted heating units are:

  • with a closed combustion chamber (without chimney design);
  • with an open combustion chamber (a chimney must also be installed).

Wall-mounted units with a closed combustion chamber are safer equipment for heating, since oxygen will not be taken from the living space. But for them, it will also be necessary to make a forced removal of combustion products. The easiest way is to install a coaxial pipe. It is made in such a way that it can simultaneously remove combustion products and deliver oxygen to the combustion chamber.

Rice. 6

Also, gas wall-mounted units must have a built-in fan. They are considered the most safe option for use, but, unfortunately, they are more expensive than boilers with an open combustion chamber.

The disadvantage is that Ariston double-circuit gas heating units, when heating water, stop heating the living space for some time.

Floor models are made specifically for industrial buildings, but they cannot heat water at the same time. Therefore, if, after all, heating water is a prerequisite, then you will also have to acquire a boiler that can be connected to a gas heating unit.

All wall and floor equipment meets all safety regulations. Wall-mounted gas boilers are fully adapted to the conditions of the gas distribution system of Russia, as well as the CIS countries. And, despite the fact that there is often reduced gas in Russia, wall-mounted units will still continue to work perfectly.

Before purchasing a wall-mounted or floor-standing unit, you must first familiarize yourself with the necessary information, and only then proceed directly to the purchase.

The premises in which the gas boiler will operate are specified in SNiP 31-02-2001, DBN V.2.5-20-2001, SNiP II-35-76, SNiP 42-01-2002 and SP 41-104-2000 - these documents eliminate or minimize any emergency situations. Premises for placing gas boilers fall under the classification of fire and explosion hazards, therefore, when designing, planning, installing and setting up equipment for gas heating all requirements for the room for installing a gas boiler must be strictly observed.

General requirements for the installation of gas appliances

In the room intended for the installation of a gas boiler, according to the above standards, there must be good natural lighting: per 1 m 3 there must be at least 0.03 m 2 of window opening area (but not windows - partitions, frames and imposts are not taken into account). It is necessary to equip the room with a system supply and exhaust ventilation according to the following rules: the total volume of forward and reverse air flows per hour, multiplied by 3, is equal to the volume of the entire exhaust device. In addition to the window equipped with a window, a door with access to the street is installed in the room. The table shows the requirements for room volume:

Attention!

For gas-fired units with a power of more than 6000 W, 0.2 m3 should be added for each extra unit of power.

Supervisory requirements for the premises for installing a gas boiler stipulate that the operation of any appliances for heating an apartment is permitted on each floor of a multi-storey building and in any room of the apartment. Kitchens in multi-storey buildings, since they are already equipped with appropriate communications. The only condition- the total thermal power of all devices for heating water and heating the apartment (boilers, boilers, heating elements, heating radiators, batteries or registers) shall not exceed a total of 150 kW.

The ceiling height in the room is 2 meters or more. The room in which the gas boiler will be installed and operated must be separated from adjacent rooms by solid fire-resistant walls. Material for walls or partitions must have a fire resistance time limit of 0.75 hours (45 minutes). The boiler room must be designed so that in the event of an operational fire there is no possibility for the fire to spread throughout the apartment.

Attention!

Gas boilers of the TLO brand, operating on the principle natural circulation coolant, can be installed and should be used only in the basement of the house or in the basement.

Installation of a gas wall-mounted boiler - kitchen requirements

  1. Ceiling - 2 meters and above.
  2. The total volume of the kitchen is more than 7.5 m 3, ventilation is equipped, a window is installed and there is a door opening onto the balcony.
  3. For air exchange, it is necessary to equip a grille at the bottom of the wall or door that goes into next room, grid area – at least 0.02 m2.

To install a gas boiler in the kitchen, you may need permission from the gas service.

If the kitchen in the apartment does not meet the requirements of SNiP, then gas heating equipment can be installed and operated only with the permission of the gas supervision authority.

The existing rules for installing a gas boiler in a private house largely repeat the requirements for boilers that operate in apartments multi-storey buildings. The differences are caused only by the fact that often in a private house for heating equipment a separate room or building is allocated, which is subject to additional requirements listed below.

Rules for installing a floor-standing gas boiler

  1. In a house under construction, it is necessary to plan a separate room for installing a gas-fired boiler. The room should have a natural flow of air through a grille in the door or through a hole in the wall.
  2. A separate hole must be made for supply and exhaust ventilation - it must be located under the ceiling.
  3. A hole in the wall for the chimney pipe, a hole below the chimney for a soot brush (for cleaning the chimney pipe), which is made below the main chimney by 20-30 cm.
  4. The chimney is made sealed so that smoke and carbon dioxide do not flow back into the room. For tightness inside big pipes A pipe of smaller diameter is installed in the chimney, through which gas combustion products are discharged.
  5. The room intended for installation and operation of a gas boiler must be spacious and provide easy access and operation, maintenance and repair of the boiler. The floor in the furnace room must be made of non-combustible materials - concrete screed, natural stone, paving stones. The furnace room must be connected to the water supply for the operation of the water heating device, and be equipped with a sewerage system.
  6. The area of ​​the room for the boiler is 4 m2, the height of the ceilings in the room is at least 2.5 m2.
  7. Exterior door should be 80 cm wide.
  8. The top of the chimney should be higher than the roof. The cross-section of the chimney pipe must be larger than the diameter of the boiler outlet.
  9. To supply power, the boiler room must be equipped with an electrical panel with grounding.
  10. The gas line is brought into the room in advance. For everyone gas appliance a separate valve must be installed.
  11. The walls of the boiler room are plastered - it is strictly prohibited to decorate the walls with flammable materials (MDF, fiberboard, plastic).

It is prohibited to store flammable liquids and objects near the furnace room and in the room itself. The foundation under (a gas heating unit or a gas heating water heating unit) should not freeze in winter, therefore its depth should be below the level of soil freezing in a given region. Air from vent must be clean, that is, the chimney must be located far from the ventilation hole. The room or building in which the gas boiler is installed cannot be equipped for other purposes.

Rules for installing wall-mounted gas boilers in an apartment

Typically, in an apartment, a gas boiler is installed in the kitchen, since it already has a gas line, water supply and sewerage. That is, a priori, all requirements for the installation of gas equipment have already been met - all that remains is to connect the boiler. This state of affairs automatically reduces the cost of laying engineering communications and energy resources. It is prohibited to install a gas boiler in premises in high humidity– in the bathroom, laundry room, etc.

There are several additional requirements for wall-mounted boilers:

  1. The wall or partition for hanging the boiler must be able to support it - on plasterboard or other light partition Equipment cannot be suspended.
  2. If the wall is decorated with flammable materials (wallpaper, vinyl, plastic, MDF, fiberboard), then a 3 mm thick gasket of non-flammable material is installed between the wall and the wall. In this case, the boiler must be secured with special hardware that ensures a distance from the boiler body to the wall of at least 4-5 cm.
  3. The minimum distance from the boiler to the ceiling and walls of the room is 0.5 meters. The distance from the boiler to the floor is 0.8 meters.

Before installing and starting up gas equipment, you must obtain all relevant documents. The main condition when installing a boiler in a private house that runs on gas is that an agreement on connecting the gas main is first concluded, and a project for the installation of gas equipment and gasification of the house is drawn up. These documents are developed and approved by the gas supplier in the region.

Gas still remains the cheapest type of fuel. Accordingly, the cheapest heating is obtained precisely at natural gas. True, installing a gas boiler is associated with certain difficulties - the premises must comply with fire safety standards.

To install powerful gas boilers, a separate room is required

Gas boiler installation standards

To avoid any troubles when putting the gas boiler into operation, it is necessary to select the installation location in accordance with current standards. The installation of a gas boiler in a private house (single-family or semi-detached) is regulated by SNiP 31-02-2001, and the installation rules in apartment buildings are prescribed in SNiP 2.08.01.

For private houses

According to the standards, a gas boiler can be installed in a ventilated room, which is located:

  • on the first floor of the house;
  • in the basement or basement;
  • in the attic:
  • gas boilers with a power of up to 35 kW (according to MDS 41.2-2000 up to 60 kW) can be installed in the kitchen.

There are currently two standards in force regarding the installation of boilers in the kitchen. According to one document, heating devices with a power of no more than 35 kW can be placed, according to another - no more than 60 kW. And we are talking only about heating devices. Gas stoves or other equipment using gas is not taken into account.

What to do? You need to find out what standards your GorGaz adheres to. After all, it is their representatives who will accept the equipment into operation. Actually, the designer should tell you all the details, but it is also advisable to know this - you will need to prepare the room for installation.

Where to put

Now let’s talk about where and how gas equipment of different capacities can be located. We will talk about gas boilers and their power is summed up:

  • with a power of up to 150 kW inclusive - in a separate room on any floor, including the basement and basement;
  • from 151 kW to 350 kW inclusive - in a separate room of the first, basement or ground floor, as well as in a separate attached room.

More powerful installations are not used in private homes.

Requirements for kitchens in which a gas boiler is installed

When placing a flow-through in the kitchen gas water heater or heating boiler on gas with a power of up to 60 kW, the room must meet the following standards:


There is one more thing that is not specified in the standards, but which exists: installing a gas boiler is allowed only in a room with doors. In the light latest trends- removing partitions and making doors instead - this could be a problem. Without a door, the permit will not be signed. The solution is to put or . Another option - glass doors. They do not “load” the interior, but they are perceived exactly as doors.

All these requirements must be met. If there are violations, they simply won’t sign the acceptance certificate for you.

Requirements for individual premises

They are similar, but there are some differences:

  • Ceiling height - at least 2.5 m;
  • The volume and area of ​​the room are determined by ease of maintenance, but should not be less than 15 m3.
  • Walls leading to adjacent rooms must have a fire resistance limit of 0.75 hours and zero limit for the spread of fire through the structure (brick, concrete, building blocks).
  • An exhaust hood with the same requirements: for outflow - three times exchange, for inflow in the same volume, plus air for combustion.
  • The room must have a window. The glass area is at least 0.03 m2 per cubic meter of volume.

If equipment is installed with a power of 150 kW or more, one of mandatory conditions- availability of access to the street. A second output can be equipped - in utility room(not residential). This could be a storage room or a hallway. Doors must be fireproof.

Please note that when calculating windows, the glass area is considered, not the size of the window opening. Moreover, in some cases they require at least one glass with an area of ​​at least 0.8 square meter. If enlarging the windows is problematic, you can make a similar window in the door (the regulations do not say that it must be in the wall).

How to attach boiler rooms

Sometimes it is not possible to allocate a separate room in the house. In this case, the boiler room is added. The standards for ceiling height, volume, glazing and ventilation remain the same as for individual rooms, only specific standards are added:


Please note that the extension must be registered. Without official documents No one will give you gas on it. And one more thing: when designing it, lay down all the standards without deviations, otherwise they won’t accept it. If the installation of a gas boiler is planned in an existing room, they may turn a blind eye to some deviations or offer some compensation (if there is a missing volume or height of the ceilings, they may be asked to increase the glazing area). For newly constructed buildings (and extensions too) there are no such discounts: they must include all standards.

Combined kitchens

Today it has become fashionable to have or. It turns out to be a single large space in which it is easy to implement design ideas. But the gas service regards such premises as residential and prohibits the installation of gas equipment.

It will not be possible to solve the problem with a studio apartment, but with a combined apartment there is a solution. If you are just planning to combine the kitchen and living room, when preparing the documents, call the resulting room kitchen-dining room. This premises is not residential, so there will be no restrictions. If the papers have already been completed, you can try to redo them or go the other way - install sliding partition. True, in this case, the documents will need to be redone.

Place for installing a gas boiler

If we talk specifically about apartments, then gas boilers are installed in them, mostly in the kitchens. There are all the necessary communications: running water, gas, a window and an exhaust hood. It remains only to determine suitable place for the boiler. For this installation, wall-mounted (mounted) boilers are used. They are installed on several hooks fixed to the walls (usually included in the kit).

As for installation in other areas of the apartment or house, as a rule, none of them meet the requirements. For example, there is no window in the bathroom natural light, the corridor usually does not fit in size - there is not enough tolerance from the corners or to the opposite wall, usually there is no ventilation at all or it is insufficient. The problem with storage rooms is the same - there is no ventilation and windows, there is not enough volume.

If there is a staircase in the house to the second floor, the owners often want to place the boiler under the stairs or in this room. In terms of volume, it usually passes, but in terms of ventilation it will have to be very powerful - the volume is considered to be at two levels and it is necessary to ensure its threefold exchange. This will require several pipes (three or more) of a very large cross-section (at least 200 mm).

Once you have decided on the location for installing the gas boiler, all that remains is to find a place for it. It is selected based on the type of boiler (wall-mounted or floor-standing) and the manufacturer’s requirements. The technical data sheet usually specifies in detail the distances from the wall on the right/left, the installation height relative to the floor and ceiling, as well as the distance from the front surface to the opposite wall. U different manufacturers they may vary, so it's worth reading the manual carefully.

Installation standards according to SNiP

  • Gas boilers can be installed on fireproof walls at a distance of at least 2 cm from it.
  • If the wall is fire-resistant or combustible (wooden, frame, etc.), it must be protected with fireproof material. This can be a three-millimeter sheet of asbestos, on top of which a sheet of metal is fixed. Plastering with a layer of at least 3 cm is also considered as protection. In this case, the boiler must be hung at a distance of 3 cm. The dimensions of the fireproof material must exceed the dimensions of the boiler by 10 cm from the sides and bottom, and from the top must be 70 cm larger.

Questions may arise regarding asbestos sheet: today it is recognized as a material hazardous to health. You can replace it with a layer of cardboard from mineral wool. And also keep in mind that a fireproof base is also considered ceramic tiles, even if it is laid on wooden walls: a layer of glue and ceramics provide just the required fire resistance.

The installation of a gas boiler relative to the side walls is also regulated. If the wall is non-flammable, the distance cannot be less than 10 cm. For flammable and non-combustible walls, this distance is 25 cm (without additional protection).

If a floor-standing gas boiler is installed, the base must be non-flammable. On wooden floor make a non-flammable stand. It must provide a fire resistance rating of 0.75 hours (45 minutes). These are either bricks laid on spoons (1/4 of a brick), or thick ceramic floor tiles, which is placed on top of an asbestos sheet fixed to metal sheet. The dimensions of the non-combustible base are 10 cm larger than the dimensions of the installed boiler.