Why the gas water heater does not light up: reasons, possible breakdowns, troubleshooting methods. Repair of a Beretta geyser: does not ignite, does not heat water and other malfunctions How to clean the igniter of a Beretta geyser

Everyone in our country knows about the service life of Beretta geysers. This is one of the most popular brands from Italy, whose products have become in demand all over the world. When purchasing such equipment, you should think not only about its technical qualities, but also about who will perform maintenance and adjustment of the device. If you need a quick and high-quality repairs Beretta geyser, please contact the staff of our field workshop for help.

Setting up Beretta devices of any type

Manufacturers have made sure that all warranty period users did not need to repair Beretta geysers. But over the years, the internal mechanism wears out and requires cleaning, adjustment, and replacement of some parts. The work of returning the equipment to its former performance will be undertaken by the specialists of our Remrada mobile workshop. Our specialists work from home, completely eliminating the need for clients to transport products to service center for repair of Beretta geysers. There are other privileges of cooperation with us.

  1. Use of high-quality new replacement components.
  2. Repair of Beretta geysers is carried out on the same day you contact the workshop. Within a few hours, a specialist will arrive at the specified address.
  3. An employee of our company will carry out repairs at any time convenient for you, since we work around the clock, seven days a week.
  4. We provide a long-term guarantee (up to 12 months) for the repair of Beretta geysers by our craftsmen.
  5. We eliminate breakdowns of any complexity - from repairing the gearbox to cleaning the mechanism.
  6. Repair of Beretta geysers is carried out by experienced specialists (work experience of at least 7 years).

Help from Remrada professionals

If you need urgent repair of a Beretta Idrabagno, repair of a Beretta Aqua or any other model, contact the specialists of our mobile workshop. This can be done online or by phone at any convenient time. Our managers will answer all questions regarding equipment repair and maintenance and will announce the preliminary cost of services.

Let’s say right away that repairing a gas water heater, like any other gas equipment, is a matter exclusively for professionals. But, although repairing speakers with your own hands is not allowed, knowledge is never superfluous. The ability to determine on your own what exactly is broken, what this breakdown threatens, and what the repair could cost will not hurt anyone. What kind of breakdowns of geysers happen, and what “symptoms” are they accompanied by?

How does a gas water heater work?

To begin with, before getting acquainted with the basics of fault diagnosis, it is useful to find out how the gas water heater is designed; repairs will largely depend on the device. We will not delve into the intricacies of the design of many speaker models; we will limit ourselves to just getting acquainted with the general principles.

Centralized hot water supply appeared relatively recently by historical standards. The issue of heating water at home has been resolved in various ways, but the most common one we had was a storage solid fuel heater - the so-called titanium. Titanium was heated with coal, less often with wood or fuel oil. The water in the boiler had to be heated in advance. So it took at least an hour to take a bath. Of course, using such a device was very inconvenient. The problem of quickly heating water was solved in geysers.

The operation of the column is accompanied by popping noises

Possible reasons are as follows:

      • The gas pressure is too strong, the burner ignites too actively, causing the flame to fail.
      • The gas pressure is too weak, air gets inside the burner, which is accompanied by a micro-explosion.

The burner needs cleaning and adjustment. In principle, nothing complicated, but you don’t need to take on this work yourself; repairs to the geyser should be carried out by a specialist.

Low water temperature

Insufficient water heating may be due to low power columns. Do not open the hot tap in the bathtub, sink and kitchen at the same time, or buy a more powerful unit.

Another possible cause may be a clogged burner, as indicated by yellow flame. Call a gas technician, a specialist will solve this problem in an hour.

When you turn on the speaker you smell gas

This is already serious and threatens with the most dire consequences. Immediately turn off the column, turn off the gas supply valve, ensure that the room constant ventilation, call the emergency service (104) and wait for the brigade to arrive.

In conclusion, once again I would like to remind you about safety. Do not attempt to disassemble, clean or repair gas equipment on one's own. This work is for qualified professionals only.

Geyser of Italian manufacturers after long-term operation, like all others, tends to break. Manufacturers of flow-through gas water heaters, in order to improve technical specifications and operational safety, gradually complicated the design. In order to protect consumers from carbon monoxide poisoning, a draft sensor was installed. And so that plate heat exchanger didn't collapse from high temperature and high pressure, a temperature sensor for water was installed. All complications are aimed at only one thing - to cut off the gas from the pilots in order to avoid emergency situations. Therefore one of the most frequent breakdowns- This geyser Beretta does not want to light up.

For clarity, in some expensive models installed a display that displays indicators of water temperature, time, fault code, etc. The hour is not far off when the column will ask when entering the bathroom: “Would you like to take a shower?” Let's look at the design of the Beretta column and the most common malfunctions.

The design principle of the B eretta instantaneous water heater is no different from other instantaneous water heaters. There is no need to list all the components. Let's focus on those that often break down:

    solenoid valve;

    heat exchanger;

    hydraulic group;

    pilot burner;

    thermocouple;

    smoke exhaust thermostat.


Construction of a Beretta gas water heater

The operating principle of instantaneous water heaters is based on the pressure difference arising from the flow of liquid through a Venturi tube. The greater the water flow that occurs when opening the tap, the greater the electromagnetic gas valve passes gas to the burner. Here main role plays a membrane that presses on the rod.

See the design of the B eretta geyser in this video:

Beretta gas water heater: malfunctions solutions, repairs

Let's try to put them into a sequential list possible reasons, affecting the ignition of the Beretta gas water heater.

Igniter does not ignite gas

One of the possible breakdowns is that the piezo ignition button does not work, there are no clicks and there is no spark. In order not to be left without hot water, you can use matches for a while. If necessary, replace the faulty button with a new one.

Thermocouple does not work

A thermocouple is a sensor consisting of two dissimilar metals. Its main purpose is to measure the flame temperature. The thermocouple plays the role of a sensitive element through which a direct current passes when heated. It should be noted that at the moment of heating, a current of hundredths of a volt passes through the thermocouple.
A sensitive device detects the difference and supplies voltage to the solenoid valve, which supplies gas to the pilot pins. The thermocouple cannot be repaired at home; it must be replaced with a new one.

The solenoid valve is broken

The valve consists of a coil of copper wire wound and an iron rod. The rod is connected to a valve that opens the gas supply to the burner. When the required temperature is reached on the thermocouple, voltage from the batteries is supplied to the solenoid valve, which opens the gas supply. The solenoid valve in the circuit is connected to a thermocouple. And if it is faulty, the column will not work.

These precautions are taken in case the gas wick is blown out by a draft. To test the solenoid valve, it must be connected directly to the batteries. If the column lights up, then the breakdown must be looked for elsewhere.

Thermal fuse does not work

The thermal fuse consists of a bimetallic plate, which, depending on the temperature, can bend in one direction or another. It is this property of breaking electrical circuits when the permissible temperature is exceeded that is also used in other household appliances: irons, electric stoves etc. When a bimetallic plate bends, it can break the electrical circuit that supplies voltage to the solenoid valve. The thermal fuse operates constantly, and each time we turn the control knob to adjust the water temperature, we set its bend.


Water temperature sensor

If the temperature of the water in the column begins to rise above the permissible limit, the thermal fuse will break the power supply circuit of the solenoid valve. The flow of gas will stop and the column will go out. Constantly being in motion, the bimetallic plate may break and stop working. There is no way to repair it, you have to buy a new one. To check whether the thermal fuse works or not, disconnect it and short-circuit the wire terminals directly. If the column starts to work, it means it is faulty and needs to be replaced with a new one.

Radiator (heat exchanger) leaking

Radiator (heat exchanger) leakage occurs after several years of operation. The heat exchanger is made of copper pipes and soldering must be done with solder containing an admixture of copper. At home, without practice, solder copper pipe impossible. It is better to entrust the repair of a column radiator to a specialist.

First you need to find the location of the water leak. If a pipe is leaking visible side You can solder it without removing it instantaneous water heater from the wall.

Soldering can be done with either an electric or gas soldering iron.

Adviсe:

    Please note that the electric soldering iron must have a power of at least 100 W;

    gas burner, solder, solvent, rosin can be bought at a hardware store.


In order for the soldering to be of high quality, it is necessary:

    Drain the water from the column. To do this, open the shower faucet and unscrew one of the fittings to allow air into the pipes.

    Clean the soldering area from deposits of dirt and salt deposits with sandpaper.

    Clean the soldering area from grease with any solvent, gasoline, etc.

    Heat the pipe with a soldering iron to evaporate the water. As soon as the steam from the pipe at the fitting stops, start soldering.

    The solder should not spread over the copper pipe from the burner flame. And on the temperature of the copper tube.

Adviсe:

  • It is necessary to clean a copper pipe with sandpaper without much zeal, so as not to rub an even larger hole.
  • After all connections are assembled, run water into the heat exchanger. The tap in the bathroom should be open. Pay attention to its color. If it is dirty, it means that salt deposits have accumulated and the heat exchanger needs to be washed.

There is no spark when the speaker is turned on

There may be several reasons for the lack of spark:

    batteries are low;

    there is no required water pressure in the water supply;

    there is no contact between the thermocouple and the housing (check all contacts);

    The distance between the electrode and the wick in the pilot burner has increased, adjust it.


The water supply line may be clogged with salt deposits. Check the pressure by opening the faucet in the kitchen.

    Adviсe:

    • If there is no draft in the chimney, the column will not work, check the draft.

      The fine filter at the inlet to the instantaneous water heater may be clogged. Unscrew it and rinse the mesh under high pressure water

    .

Cleaning the Beretta gas water heater from carbon deposits and soot

It is necessary to clean the instantaneous water heater from soot and soot regularly, without waiting for the nozzles to become clogged with soot and soot. Evidence of this is the red color of the flame in the burners. Use soft metal brushes to clean burners. Shine a flashlight from bottom to top at the heat exchanger. If soot has accumulated between the plates, remove it with a thin wire. Soot on the heat exchanger plates plays the role of a heat insulator. The more soot, the greater the gas consumption.

Tips: Clean your Beretta geyser from soot and deposits regularly, at least once every three months.

Our geyser repair specialists carry out the entire package of work regarding Beretta geysers, such models as:

  • BERETTA Aqua 11; Aqua 14
  • BERETTA Aqua 11i; Aqua 14i
  • BERETTA IDRABAGNO 17; IDRABAGNO 17i
  • BERETTA IDRABAGNO 13 ESI ; IDRABAGNO 17 ESI

Is your BERETTA gas water heater broken?

Italian geysers Beretta (Beretta) have long been known in Russia and are quite popular among those who have used this equipment. Beretta Idrobagno series and Aqua series speakers are produced in several power and ignition options, including varieties of Beretta speakers with closed camera combustion. Beretta gas water heaters are reliable structural elements, stability of operation when water or gas pressure drops. Long-term use of a water heater from this company shows a number of malfunctions: failure of the device due to clogging of the igniter, which affects the column turning on and off during operation; no spark after opening the water tap. All these signs indicate wear of the control unit.

The main malfunctions of BERETTA geysers may be the following:
1. the igniter does not light (when the button is released, it goes out, in case of piezo ignition);
2. when turned on, there is a clap; The main burner does not light up(in case of piezo ignition);
3 . while the column is running the main and pilot burners are switched off;
4 . the column does not dial desired hot water temperature;
5. no spark, when opening a hot water tap;
6. the column turns off after ignition in 1-2 seconds;
7. there is a spark, but does not ignite (in the case of electronic ignition);

will perform high-quality repairs at home for your Beretta speaker at a time convenient for you! Departure of the master in a short time in Moscow and the Moscow region. We carry out repairs only with original spare parts. We have the most affordable prices. A specialist from our company will help you solve all the problems associated with the BERETTA gas water heater. Our employees undergo annual training and have the appropriate certificates, and are annually recertified for access to hazardous gas work.

How to repair a Beretta gas water heater if it does not burn or heat? In this article, we have collected the main causes of breakdowns and given tips on how to eliminate them.

Beretta has been manufacturing heating equipment for 60 years. Flow heaters are an economical way to receive hot water, but after long-term use the equipment breaks down.

Basic faults and DIY repairs

Let's look at the main problems with the Beretta boiler, as well as ways to fix them without contacting a service center.

Igniter problems

When the water heater is running, the pilot light should be lit continuously. If you stop holding the gas control knob and the igniter does not light, this indicates problems with the automation. The first thing to do is turn off the water and gas supplies.

The flame in the burner occurs when the igniter heats the thermocouple. If it goes out, the protection system is triggered - the column turns off. Otherwise, there is a risk of carbon monoxide entering the room. A similar problem can be caused by the following fuse parts:

  • Thermocouple.
  • Overheat sensor.
  • Solenoid valve.

The protection is triggered when the equipment is rarely serviced. See if it's time to clean the igniter: clogs often occur in dusty and damp areas. What indicates the need for cleaning:

  • The burner lights with a loud bang.
  • The flame is not blue, but has red tips.
  • The burner constantly goes out.

How to clean:

  • Turn off the gas supply, remove the column casing.
  • You will see the pilot light; it may be clogged with soot.
  • Unscrew the traction sensor and gas supply tube.
  • Remove and clean the nozzle.
  • Rinse under running water tee, other parts.
  • Reassemble the igniter in reverse order.

Additionally, you can check the solenoid valve, but you will need a multimeter for this.

Thermocouple faults

A thermocouple is an alloy of two types of metal that serves to protect equipment from damage. The part opens and closes the gas supply to the burner. When a thermocouple heats up, its plates expand, generating EMF (electromotive force). This force is enough to open the solenoid gas valve. When heating stops, the product cools down, and the supply is shut off.

For self-repair you will need spare parts. Please note that different models(for example, "Idrabanyo 11") they may differ.

  • The thermocouple is located next to the igniter. Secure with a nut.
  • Loosen the strap that holds the part.
  • Now unscrew the thermocouple nut counterclockwise.
  • Unscrew the contact screw. He is with reverse side adjustment knob.
  • Disconnect the wiring.
  • Install a new element.

Solenoid valve failure

The valve is a coil with a rod and a spring that serves as protection against gas entering the room. There is a seal around the coil to better seal all the cracks. IN in good condition the valve is closed when the equipment is turned off. When the circuit starts and the membrane is activated, the control module sends a signal to the valve to open - gas enters the burner.

Replacing the part is easy; just unscrew the four mounting screws with a screwdriver.

Thermal fuse problem

It is triggered when the column overheats. Try lowering the room temperature by opening the windows. To check the fuse, you need to close its contacts together. If the column turns on, it means it's overheating. If not, the part is replaced.

Heat exchanger clogged and leaking

If the equipment does not heat the water well or does not heat the water at all, you need to clean the radiator. The pressure may also decrease because plaque narrows the passages in the coil tubes.

For cleaning you need:

  • Remove the product casing.
  • Drain the radiator.
  • Unscrew the fastening bolts.
  • Immediately clean the assembly from dust using a brush. To remove scale, use citric and hydrochloric acid.
  • Drive the solution hydrochloric acid along the coil with a pump or watering can.
  • Dilute citric acid in water, pour inside.
  • After 30 minutes, rinse everything with water.

Leaks occur due to corrosion. Manufacturers try to reduce the cost of production by adding impurities to copper for the radiator. The walls become thin and heat up unevenly. As a result, burnouts appear. An abundance of green spots on the surface indicates an imminent leak.

The accident can be eliminated by soldering. To do this, use a gas burner (for thick-walled radiators) or a soldering iron. You will also need solder and flux.

Can be used cold welding or a tin patch. If nothing can be done to help, the heat exchanger is replaced.

When choosing a replacement part, be careful to ensure that the new radiator has not been soldered or repaired.

No spark when turned on

What caused it:

  • Problems with the membrane. As we already wrote, the membrane starts the gas supply valve. To do this, it must be intact and elastic. If it is deformed and torn, the burner will go out or will not light at all. Replace the rubber part with a silicone one, it will last longer.
  • In equipment with electronic ignition. The power supply is located at the bottom of the case. Open the cover and replace the batteries.
  • Insufficient pressure cold water. Turn the adjustment knob to the right and down.
  • Hold the piezo ignition button longer. Check his contacts: maybe they have moved away.
  • The ignition electrode has moved and is on long distance from the wick. Adjust the position.
  • Check if it is open gas tap. If not, then open it.
  • No traction. Test your guess by holding a lit match to the window. If the flame burns steadily, contact your utility company to have the chimney cleaned.

This typical faults geysers "Beretta". Depending on the situation, other troubles can occur. Take care of your equipment to avoid such problems.